Where required, fire protection systems shall be monitored by an approved supervising station in accordance with NFPA 72.ĩ01.6.1 Automatic sprinkler systems. It shall be unlawful to occupy portions of a structure until the required fire protection systems within that portion of the structure have been tested, inspected, and approved.ĩ01.6 Supervisory service. Copies of test records and certificates shall also be maintained at the job site and made available to the inspector conducting the fire protection systems final inspections. Test results shall be documented and certificates shall be submitted to the building official and the fire official upon completion. The building official may require that the acceptance tests be conducted in the presence of a certified building inspector or certified fire protection system inspector. Required acceptance tests shall be conducted at the expense of the owner or the owner's representative. Fire protection systems shall be tested in accordance with the requirements of this code, the fire code, and the applicable standards referenced in this code.
![residential fire sprinkler system design ohio residential fire sprinkler system design ohio](https://autosprink.com/img/product/calculate-thumb.jpg)
Prior to issuance of the certificate of plan approval, the building official shall communicate with the local fire official to verify that the proposed threads are compatible with those currently used by the fire department.ĩ01.5 Acceptance tests. Threads provided for fire department connections to sprinkler systems, standpipes, yard hydrants or any other fire hose connection shall be compatible with the connections used by the local fire department. Termination of fire alarm monitoring services shall be in accordance with Section 901.9 of the fire code.ĩ01.4 Threads.
#Residential fire sprinkler system design ohio code
Persons shall not remove or modify any fire protection system installed or maintained under the provisions of this code or the fire code without approval by the building official with input from the fire official as outlined in Sections 106.1.2(5) and 901.2.1.1. When the building official or the fire official has indicated an intention to have personnel witness acceptance testing conducted in accordance with Section 901.5or during the final inspection process, it is the responsibility of the owner or the owner's representative to provide advance notice of when the tests are scheduled to both the building official and the fire official.ĩ01.3 Modifications. In the absence of timely input from the fire official during the plan review process, the building official shall proceed as outlined in Section 107.5.1.ĩ01.2.1.2 Coordination. The building official shall evaluate the local fire official's comments and incorporate items of noncompliance with this code into the building department plan review process as outlined in Section 107.6. In jurisdictions where the local fire official has requested the opportunity to provide input into the fire protection system approval process conducted by the building official, the owner or the owner's representative is required to submit a copy of construction documents related the fire protection to the local fire official for review in accordance with Section 106.1.2(5). Prior to the start of fire protection system installation, alteration, repair, or removal, the owner or the owner's representative shall make application and obtain plan approval from the building official for the proposed work in accordance with Section 106 of the building code.ĩ01.2.1.1 Input from the fire official.
![residential fire sprinkler system design ohio residential fire sprinkler system design ohio](https://www.vedard.com/images/design-fire-alarm-system.png)
![residential fire sprinkler system design ohio residential fire sprinkler system design ohio](https://s3.amazonaws.com/finehomebuilding.s3.tauntoncloud.com/app/uploads/2018/11/16122957/sprinkler-head.jpg)
Fire protection systems shall be installed, repaired, operated and maintained in accordance with this code and the fire code.Īny fire protection system for which an exception or reduction to the provisions of this code has been granted shall be considered to be a required system.Įxception: Any fire protection system or portion thereof not required by this code shall be permitted to be installed for partial or complete protection provided that such system meets the requirements of this code.ĩ01.2.1 Approval of fire protection systems. The provisions of this chapter shall specify where fire protection systems are required and shall apply to the design, installation and operation of fire protection systems.ĩ01.2 Fire protection systems.